A serial dilution lowers the concentration of a sample in equal steps, for example 1:10 each time. It is used when a culture is too dense to count or plate directly, so that at least one dilution gives a countable number of separate colonies.
Sample (culture or library)
Sterile diluent (LB broth, saline or water)
Sterile tubes and a micropipette with sterile tips
Marker
Label tubes with each dilution (1:10, 1:100, 1:1000 and so on).
Add the diluent to each tube; (for 1:10 steps, 900 µL per tube).
Add (100 µL) of the sample to the first tube and mix well. (This is a 1:10 dilution).
With a fresh tip, move 100 µL from the first tube into the second and mix. This is 1:100.
Repeat down the series, changing tips every time.
Plate a set volume from the dilutions you want to test.
After incubation, count plates with roughly 30–300 colonies and multiply by the dilution factor to estimate the original concentration.
Mix each tube thoroughly before taking the next transfer.
Changing tips each time is essential; carry-over throws off every later dilution.
A 1:2 dilution works the same way, using equal volumes of sample and diluent.